BPC/VPC Load Box Assembly.
The BPC/VPC load box (Figures 3-12, 13) is a load for testing the
Battery Power Conditioner (BPC) or the Vehicle Power Conditioner
(VPC).
The power conditioner output cable connects to the load
assembly connector J1. Load assembly test jacks J2 and J3 are used
to measure +4.8 VDC. The jacks are connected across an internal 3.16
ohm load resistor.
Load assembly test jacks J4 and J5 are used to
measure +16.8 VDC.
The jacks are connected across an internal 13.7
ohm load resistor.
Figure 3-12.
BPV/VPC Load Box Assembly.
Figure 3-13.
BPC/VPC Schematic
62
MM4812