LESSON
PRACTICE EXERCISE
ANSWER KEY AND FEEDBACK
Item
Correct Answer and Feedback
1.
B. Inhabited building distance.
facilities (page 4, para 4.b.(1)(d)).
2.
A. Loading dock.
Transfer pads used for containerized munitions shall use loading dock QD requirements (page 8,
para 6.a.).
3.
D. 800 feet (fragment).
Most fragments produced by detonations of this class/division will fall within one of the four
specified minimum distances: 400, 800, 1200, and 1800 feet. These are expressed as (04), (08),
(12) and (18), with the class/division-(08) 1.2- to indicate the minimum safe distance of 800 feet
(page 11, para 9.f.(3)(b)).
4.
C. Aboveground magazine distance.
For loading dock to loading dock, the aboveground magazine distance applies (page 7, para
5.h.(2)).
5.
A. Toxic effect.
The major hazard expected from 6.1 items is the toxic effect of the agents if they are involved in
an accident or fire (page 15, para 9.f.(6)(b)).
MM0150