LESSON 4..................................Troubleshooting Procedures
All references are to TM 11-665, unless otherwise indicated.
1. a--para 83a
2. d--para 83a
3. a--para 83a
4. d--para 83a
5. b--para 83b
6. c--para 83b
7. d--para 84a(l)
8. a--fig. 134
9. b--para 84a(2)
10. c--para 84a(2), (3)
The buffer-doubler tank circuit (C32-L7) is tuned to the second harmonic of the
This frequency, which is twice the oscillator frequency,
becomes the input signal to the intermediate power amplifier (IPA) With the IPA
tank circuit tuned to the second harmonic of the input frequency the output from
the IPA will be the fourth harmonic of the oscillator frequency.
11. d--para 84a(3)
12. d--para 84a(3)
13. a--para 84a(3)
14. c--para 84a(3);Addendum 1, para 9c(5)
15. c--Addendum 1,para 4b(4)
16. d--Addendum 1,para 4b(1) thru (7)
17. d--Addendum 1,para 9a
18. d--Addendum 1,para 11
19. d--Attached Memorandum, para 4-1
20. d--Attached Memorandum, para 4-1c(2)
321 S
45