(b)
An abnormal reading would tell us that R36 should be replaced, then repeat the
functional test.
(11)
To take the next resistance measurement you will need to locate T3 (white
terminal) and to check the resistance between it and TB1-9. A normal reading should be 40-
60 ohms. An abnormal reading would tell us to check the value of R34, R36, and R37 and to
replace the defective resistor(s). (See Figure 11.)
Figure 11. T3, white terminal.
(12)
Measure the resistance between J-19B (MK-994/AR) and COMM CONT 2, TB1-
24.
(a)
Normal reading: Short (less than 0.5 ohm).
(b)
An abnormal indication would mean for you to check for a faulty wire, continuity
test and repair, then perform functional test.
d.
Subtest 4. Fault code 1|1 covers all other functions.
(1)
To familiarize you with using the troubleshooting charts found in your technical
manual, we will perform the final subtest using those charts from TM 11-5821-262-35.
NOTE:
Use TM extract.
(2)
Using the TM extract, carefully go through and perform each step of Subtest 4 for
"All Other Functions."
28