(3) Low current.
23. Slot coupling.
a. Slot coupling (sometimes called electron coupling) is used when we
need only a small amount of coupling.
In this method, the stream of
(Figure 81). When used to couple energy into the cavity, the slot is placed
Figure 81.
A Resonant Cavity Using Slot Coupling.
b. When used to couple energy out of the cavity, the slot is placed at
the point of maximum magnetic field, just as we did with loop coupling.
Slot coupling therefore, has the same characteristics as loop coupling.
They are as follows:
(1) High current.
116