c. Locate the REMOTE-LOCAL
switch
S-4203
on
control
monitor
C-
2124A/FPN-40 (Figure 10).
d. Locate the HIGH VOLTAGE OFF button S-2304 on power supply PP-2489/
FPN (Figure 9).
WARNING
PLACE REMOTE-LOCAL SWITCH S-4203 TO THE LOCAL POSITION
AND DEPRESS TEE HIGH VOLTAGE OFF BUTTON BEFORE
PROCEEDING TO STEP E.
IF THE RECEIVER CHASSIS IS
PULLED FORWARD WHILE HIGH VOLTAGE IS ON, DANGEROUS
ARCHING WILL OCCUR.
e. Locate
and
unlatch
the
release
handle
on
the
receiver
chassis
(Figure 38).
Figure 38.
Component drawer handles.
44