Figure 37.
Rc greater than RL.
e. Summary of waveforms. The following chart summarizes the charge and
discharge waveforms during the three conditions
Figure 38.
Charge and Discharge Waveforms.
19. An ATL is used to introduce delay.
When an ATL is used to delay a pulse some predetermined length of
time, we call the ATL a delay line.
You have seen how an ATL introduces
this delay, and how the values of L and C determine the amount of delay.
and use an ATL to produce it.
44