LESSON 2
Figure 2-3. Inhabited Building Distance (IBD)
Magazine: Any
building or
structure except an
operating building, used to
store ammunition,
explosives, or loaded ammunition components.
Magazine Distance: The minimum distance permitted between any two storage magazines. (See
figure 2-4.)
Intermagazine Distance: The minimum distance permitted between explosive locations, as
prescribed for various types and quantities of explosives. This distance should prevent propagation by
blast.
Operating Building: Any structure except a magazine in which operations pertaining to
performed.
Operating Line: A group of buildings, facilities, or related work stations so arranged as to permit
performance of the consecutive steps in the manufacture of an explosive, or in the loading, assembly,
or modification, and maintenance of ammunition. (See figure 2-5.)
18