Figure 2-10. Loosening the Eyebolt Lifting Plug.
Grasp the lifting loop on the supplementary charge and gently lift it out of the fuze well. Inspect the
supplementary charge for corrosion. Make sure that the felt pad on the bottom of the supplementary charge is
properly positioned (see Figure 2-11). If the felt pad is missing, replace it. Use fine sandpaper to remove
corrosion from the supplementary charge. If corrosion is extensive, replace the supplementary charge. Turn the
supplementary charge back and forth and listen for the sound of loose pellets inside it. If you hear any loose
pellets, replace the supplementary charge.
Figure 2-11. Inspecting the Supplementary Charge.
MM2604